空冷風(fēng)機(jī)變頻原理及故障分析
時(shí)間:2008-05-06 09:48:00來(lái)源:yangliu
導(dǎo)語(yǔ):?本文利用圖表的方法分析了直接空冷系統(tǒng)風(fēng)機(jī)變頻技術(shù)的原理,同時(shí)對(duì)應(yīng)用過(guò)程中存在的問(wèn)題和解決方法進(jìn)行了介紹,并提供了一些建議。
摘要: 為進(jìn)一步提高變頻技術(shù)在電力系統(tǒng)中的應(yīng)用水平,本文利用圖表的方法分析了直接空冷系統(tǒng)風(fēng)機(jī)變頻技術(shù)的原理,同時(shí)對(duì)應(yīng)用過(guò)程中存在的問(wèn)題和解決方法進(jìn)行了介紹,并提供了一些建議。
關(guān)鍵詞: 火電機(jī)組;直接空冷系統(tǒng);風(fēng)機(jī);變頻器
[b][align=center]Principle of Air-Cooling Blower Variable-Frequency and Trouble-Analysis
LIU Xuan
(Shanxi Zhangshan Electric Power Company Ltd,Changzhi 046021,China)[/align][/b]
Abstract: To further increase the application level of variable—frequency technology in electrical power system ,this paper an alyzes the principle of direct air—cooling blower variable—frequency technology by graph way.At the sa.rne time,it introduces the ex—isting problem and the solution in the course of appli—cation,and supplies some suggestions.
Key Words: generating unit;direct air—-coling sys—-tern;blower;variable—frequency governor
火力發(fā)電廠多采用水冷技術(shù),面對(duì)越來(lái)越緊迫的水資源缺乏問(wèn)題,我國(guó)新建大型火力發(fā)電廠都在利用直接空冷技術(shù)代替?zhèn)鹘y(tǒng)的濕冷(水冷)技術(shù)。直接空冷系統(tǒng)利用空氣直接冷卻汽輪機(jī)排汽,汽輪機(jī)排汽經(jīng)布置在空冷島頂部的散熱器后,在散熱器下部軸流風(fēng)機(jī)的冷卻風(fēng)作用下,壓力降低,溫度下降,凝結(jié)成水回到凝結(jié)水箱中,未凝結(jié)的蒸汽和空氣從散熱器頂部由真空泵抽走,避免在運(yùn)行中空冷凝汽器內(nèi)部的某些區(qū)域形成死區(qū),導(dǎo)致?lián)Q熱效果降低以及冬季凍結(jié)。
空冷技術(shù)的核心在于控制汽輪機(jī)背壓,由于火力發(fā)電是1個(gè)十分復(fù)雜的能量轉(zhuǎn)換過(guò)程,汽輪機(jī)背壓受多種因素影響,變化復(fù)雜,因此直接空冷機(jī)組多采用變頻技術(shù)來(lái)控制軸流風(fēng)機(jī)轉(zhuǎn)速,以達(dá)到調(diào)節(jié)汽輪機(jī)背壓的目的。
1 空冷風(fēng)機(jī)變頻原理分析
變頻器分交一交和交一直一交2種形式。交一交變頻器可將工頻交流直接變換成頻率、電壓均可控制的交流,又稱直接式變頻器。而交一直一交變頻器則是先把工頻交流通過(guò)整流器變成直流,然后再把直流變換成頻率、電壓均可控制的交流,又稱間接式變頻器。漳山發(fā)電有限責(zé)任公司(以下簡(jiǎn)稱漳山公司)采用的空冷風(fēng)機(jī)變頻器屬間接式變頻器,其原理如圖1所示,由主回路(包括整流器、中間直流環(huán)節(jié)、逆變器)和控制回路組成,分述如下。
[b][align=center]詳細(xì)內(nèi)容請(qǐng)點(diǎn)擊:
空冷風(fēng)機(jī)變頻原理及故障分析[/align][/b]