The SST DeviceNet Pro PC/104 interface card connects your PC/104 bus computer to DeviceNet. The Pro Card is a high-performance version of the SST DeviceNet PC/104 card and is compatible with all applications written for the SST DeviceNet PC/104 card.
Applications
Many third party software programs support the SST DeviceNet interface card for various applications including:
Operator Interface and MMI PC Control
Network Configuration,
Troubleshooting and Diagnostics
I/O Emulation
Device Development
Features
Entire DeviceNet Protocol is executed in hardware
UCMMcapable, Group 1, 2, and 3 dynamic explicit connections supported
Simultaneous execution of Group 2 Client and Server operation
All DeviceNet standard baud rates supported: 125, 250, and 500 Kbaud
Full DeviceNet implementation with Change of State and explicit messaging
DeviceNet compliance is ensured at the card level for
I/Oscanner and device applications
CustomDriver Development
SST offers two options for supporting the DeviceNet interface card: SST Common Driver Architecture (CDA) or Memory Mapped Access. The SST CDA significantly reduces software driver development time without compromising any of SST hardware specific features. The CDA supports SST ControlNet, DeviceNet, Modicon and Profibus interface cards. Memory Mapped Access is also available. SST provides an open documented memory map interface with example drivers.
Available with the SST DeviceNet Pro PC/104 Card
DeviceNet Network Analyzer and Monitor
Diagnostic Software Tools
DeviceNet Node Commissioning Tool
OPC Server
Common Driver Architecture (CDA)
Custom driver development software
Microsoft Windows 95/98/NT drivers/DLLs
Global technical support (24 hours/7 days) drivers.
Hardware Specifications
Compatible with PC/104 Bus
256 Kbytes shared RAM(16 Kbytes host interface window)
High performance 40 MHz processor with 512 Kbytes RAM, 512 Kbytes Flash
Software configurable interrupts 2/9, 5, 7, 10, 11, 12 & 15 supported
DeviceNet compatible 5-pin DeviceNet connector
DeviceNet compatible network status bicolor indicator
Compatible with CAN specification 2.0 part A
Supports CAN data rates up to 1 Mbaud
Supports all standard DeviceNet data rates: 125, 250, and 500 Kbaud
Multiple cards can be configured in the same computer
500 V optically isolated CAN interface
Operational temperature: 0 to 60 C
Storage temperature: -25 to 70C
Power requirements: +5 V +/- 5% 325mA (typical)
Connection to non-powered (3 wire) CAN networks with external 12-24 VDC
Other Reference Materials
Web Site: www.mysst.com/cards/devicenet/dn.asp
Affiliations
SST is a member of the ODVA (Open DeviceNet Vendor Association)
Data Sheets
DeviceNet Diagnostic and Configuration Software
DeviceNet OPC Server
Third Party Driver List
Certifications
DeviceNet Conformance Tested
Ordering Information: 5136-DNP-104